In brief
The trapped person presses the alarm and should stay calm inside the car. Only people trained in the rescue procedure for that lift should release them, usually the lift company's engineer. Afterwards, log what happened and do not put the lift back into use until the cause is known.
On this page
This post is for the person who runs the building, not the person inside the lift. It covers what should happen when someone is trapped, who should get them out, and what you need to do once they are safe.
Being stuck is unpleasant, not usually dangerous
Most people picture a lift falling when they think of being trapped. In reality, a lift that stops between floors has usually done exactly what it was designed to do. A fault has been detected, a safety circuit has opened and the lift has stopped where it is.
That doesn’t make it pleasant. For someone with claustrophobia, a medical condition or a child with them, even twenty minutes can feel very long. So the aim is a calm, safe release by the right people, not a fast one by the wrong ones.
What should happen, step by step
When the call comes in, the order matters. This is how it should run:
- The passenger presses the alarm. Most passenger lifts have an alarm button that connects to someone who can send help, often through an emergency phone or autodialler in the car. BS EN 81-28 is the standard for these remote alarm systems.
- Someone talks to them. Whether it is the alarm centre, your caretaker or the concierge, keeping in contact and telling them help is coming makes a real difference.
- The lift company is called. Their engineer is trained to release passengers safely for that make and type of lift.
- Nobody else forces the doors. Prising the doors open or trying to wind the lift by hand without training is how people get hurt.
- The lift stays out of use until the engineer has found the cause.
If the person is unwell, call 999 as you would anywhere else and tell the operator they are in a lift.
Who is allowed to release a trapped passenger?
This is the point that matters most. Rescuing someone from a lift means working near moving machinery and open shafts. BS 7255, the British Standard on safe working on lifts, exists because that work is dangerous for people who haven’t been trained for it.
In a lot of buildings, the caretaker or a member of staff has a key and a vague idea of how to hand-wind the lift. Unless they have been trained by the lift company for that specific lift, and the training is recorded, they should not do it. Ask your maintenance company whether they offer training for named staff, and keep the rescue instructions in the machine room or controller cabinet.
After the rescue
Once everyone is out, there is still work to do. Make a note of:
- The time the alarm was raised and the time the person was released.
- Who attended and what they found.
- The cause as the engineer explained it.
- Anything the passenger told you, such as the lift jolting before it stopped.
That record goes in the lift log book. It helps the engineer spot a pattern if it happens again, and it shows you took the incident seriously.
Does the lift need a thorough examination afterwards?
It might. LOLER, the 1998 regulations on lifting equipment, say in regulation 9 that equipment needs a thorough examination each time exceptional circumstances that could affect its safety have occurred. A routine stop because a door sensor tripped is unlikely to count. A lift that dropped, hit the buffers or stopped after water got into the shaft is a different matter.
If you are not sure, ask the competent person who carries out your six-monthly examinations. Write their answer down.
When it keeps happening
One entrapment can happen to any lift. Two or three in a few months is a warning sign. In other words, something is wearing out or being reset instead of fixed.
| What you notice | What it often points to | What to ask for |
|---|---|---|
| Stops at the same floor each time | Door equipment or a landing fault | A written diagnosis after the second call-out |
| Stops at random, often when busy | Controller or drive problems | The engineer’s view on parts availability |
| Stops after heavy rain | Water in the pit or machine room | A check of drainage and an examination |
If the answer is that parts are no longer made, it may be time to look at lift modernisation.
Fire lifts in taller residential blocks
If you are the responsible person for a residential building in England of 18 metres or seven storeys and above, there is an extra duty. Under regulation 7 of the Fire Safety (England) Regulations 2022, lifts for use by firefighters and evacuation lifts are checked monthly. If one of those lifts develops a fault that is not put right within 24 hours, you report it to the local fire and rescue service, and report again once it is fixed.
A worked example
Here is how a good response looks in practice. A member of staff in a five-storey office block is trapped between floors at 3pm. The concierge hears the alarm call and talks to them through the lift phone. The maintenance company is called and the engineer releases the passenger. The concierge logs the times.
The engineer finds a worn door roller, replaces it and notes it in the log. Because it was a minor fault, the lift goes back into service the same day. Two weeks later the same lift stops again, so the facilities manager asks for a written root cause and a quote for the door equipment.
Keep the basics in place
Most of this comes down to having a maintenance contract that works, which is what lift maintenance companies are there for. Regulation 5 of PUWER requires lifts used at work to be kept in good repair, and regular servicing is how that happens.
If entrapments in your building have become a regular event, it’s worth asking a second company for a view on the lift.